Sign In | Join Free | My burrillandco.com
Home > FTP CAT6 Cable >

Cat6 ftp Shielded Lan Cable 1000ft Solid Copper Lszh Ethernet Cable For Data Centers

Integrity Cable Co., Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Cat6 ftp Shielded Lan Cable 1000ft Solid Copper Lszh Ethernet Cable For Data Centers from wholesalers
     
    Buy cheap Cat6 ftp Shielded Lan Cable 1000ft Solid Copper Lszh Ethernet Cable For Data Centers from wholesalers
    • Buy cheap Cat6 ftp Shielded Lan Cable 1000ft Solid Copper Lszh Ethernet Cable For Data Centers from wholesalers
    • Buy cheap Cat6 ftp Shielded Lan Cable 1000ft Solid Copper Lszh Ethernet Cable For Data Centers from wholesalers
    • Buy cheap Cat6 ftp Shielded Lan Cable 1000ft Solid Copper Lszh Ethernet Cable For Data Centers from wholesalers

    Cat6 ftp Shielded Lan Cable 1000ft Solid Copper Lszh Ethernet Cable For Data Centers

    Ask Lasest Price
    Brand Name : ITI-LINK
    Model Number : ITI-CT6F-028
    Certification : UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS
    Price : 50$-100$
    Payment Terms : T/T
    Supply Ability : 2000pcs/day
    Delivery Time : 15-45 Days
    • Product Details
    • Company Profile

    Cat6 ftp Shielded Lan Cable 1000ft Solid Copper Lszh Ethernet Cable For Data Centers

    Cat6 Ftp Shielded Lan Cable 1000ft Solid Copper Lszh Ethernet Cable For Data Centers

    Product Description:

    High-performance ITI-LINK CAT6 FTP Cable (ITI-CT6F-028), 1000FT spool with 23AWG solid copper conductors and aluminum foil shielding. This shielded LAN cable delivers stable Gigabit throughput for data centers, industrial network cable runs and commercial installations. LSZH option available for low-smoke, halogen-free safety.


    Product Overview: ITI-LINK ITI-CT6F-028 is a professional-grade CAT6 FTP Cable (1000FT) designed for demanding network environments. This shielded LAN cable combines 23AWG solid copper conductors with an aluminum foil shield to deliver consistent Gigabit and above performance.
    Performance: With precision conductor dimensions (0.570±0.005) and FTP shielding, the cable minimizes EMI and crosstalk across long runs — ideal as a data center cable or industrial network cable where reliability matters.
    Structure & Materials: 4 pairs of tightly controlled twists, cross-divider for pair separation, aluminum foil shield (FTP), and robust white PVC/PE jacket. Solid copper conductors ensure low attenuation and superior signal integrity. LSZH option available for installations requiring low-smoke, halogen-free materials.
    Application Value: The 1000FT bulk spool supports flexible layouts and large deployments — from server racks to factory floor PLC connections. As a shielded LAN cable, it improves uptime and reduces troubleshooting time caused by interference.
    Brand Trust: Manufactured under ITI-LINK standards (model ITI-CT6F-028) with quality control for commercial and industrial projects. Choose this CAT6 FTP cable for dependable network backbone performance.

    Technical Parameters:

    Product Description: Cat6 ftp Shielded Lan Cable 1000ft Solid Copper Lszh Ethernet Cable For Data Centers
    Rev.: AECN Description:
    Construction Item DescriptionElectrical Property


    Conductor


    Material

    Bare Solid Copper(elongation:

    19-24%)

    Conductor Resistance at 20°C≤ 9.5 Ω / 100m
    OD23 AWGResistance unbalance within a pair≤ 2%






    Insulation

    Material


    HDPE

    Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V


    >1500 MΩ / 100m

    OD1.14 ±0.01 mmMutual capacitance5600 pF / 100m MAX
    Average THK0.24 mmCapacitance unbalance pair to ground at 800Hz or 1 kHz≤ 160 pF / 100m



    Color

    1p: white + 2 blue stripes & blueCharacteristic impedance at 100MHz100 ± 15 Ω
    2p: white + 2 orange stripes & orange

    Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or

    0.7 KV AC for 1 min


    No breakdown

    3p: white + 2 green stripes & greenMechanical Property
    4p: white + 2 brown stripes & brown



    insulation

    elongation before aging≥ 300%



    Pair Twist



    Lay & Direction

    1p: S=19.0 mm (27%)tensile strength before aging≥12 MPa
    2p: S=23.5 mm (35%)elongation after aging≥ 150 %
    3p: S=21.5 mm (31%)tensile strength after aging≥10.5 MPa
    4p: S=27.0 mm (40%)



    jacket

    elongation before aging≥ 150 %
    OD/tensile strength before aging≥ 13.5 MPa


    Inner Assemble

    LayS=90 ± 5 mmelongation after aging≥ 125 %
    Directionaccording to the drawingtensile strength after aging≥ 12.5 MPa
    Fillercross member 5.0X5.0X0.5mmTPacking
    OD/NANA
    FillerRipcord300D

    Drain WireTinned Copper





    Shield

    ShieldShield
    Construction/
    MaterialPolyester/Aluminium (PET/ALU)
    Coverage≥ 115%





    Jacket

    MaterialPVC, 50P, -20~75℃
    Hardness81± 3
    OD7.2 ± 0.2
    Average THK0.55 ~ 0.60


    Color

    Yellow
    Marking Color

    according to the customer's

    requirements

    Marking

    according to the customer's

    requirements



    Electrical Properties
    Conductor Resistance at 20°CNF EN 50289-1-2 / IEC 60189-1≤ 9.5 Ω / 100m
    Resistance unbalance within a pairNF EN 50289-1-2/ IEC 60708≤ 2%

    Dielectric Strength

    Test Voltage (cd/cd): 1.00KV DC or 0.7 KV AC for 1 min Test Voltage (cd/screen): 1.00KV DC or 0.7 KV AC for 1 min


    NF EN 50289-1-3 / IEC 61196-1-105


    No breakdown

    Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V


    NF EN 50289-1-4 / IEC 60885-1

    >1500 MΩ / 100m
    Mutual capacitanceNF EN 50289-1-5 /IEC 60189-15600pF / 100m MAX
    Capacitance unbalance pair to ground at 800Hz or 1 kHzNF EN 50289-1-5 / IEC 60189-1≤ 160 pF / 100m
    Characteristic impedance at 100MHzNF EN 50289-1-11/ IEC 61156-1100 ± 15 Ω
    Spark TestUL4442000 ± 250VOC



    Transmission Properties
    CAT 6 ANSI/TIA-568.2-D; IEC 61156-6; YD/T1019-2013



    No.


    Frequency


    Attenuation (Max)

    Propagation Delay (MAX)Propagation Delay Skew (MAX)


    Return Loss (Min)


    NEXT (Min)


    PS NEXT (Min)


    EL-FEXT (Min)


    PS EL-FEXT (Min)

    MHzdB/100mns/100mns/100mdB(on 100m)dB(on 100m)dB(on 100m)dB(on 100m)dB(on 100m)
    143.785524523.0166.2763.2755.9652.96
    285.32546.734524.5261.7558.7549.9446.94
    3105.95545.38452560.357.34845
    4167.55543452557.2454.2443.9240.92
    5208.47542.05452555.7852.7841.9838.98
    6259.51541.24524.3254.3351.3340.0437.04
    731.2510.67540.444523.6452.8849.8838.135.1
    85013.66539.094522.2149.8246.8234.0231.02
    962.515.38538.554521.5448.3645.3632.0829.08
    1010019.8537.64520.1145.342.32825
    1112522.36537.224519.4343.8540.8526.0623.06
    1220028.98536.55451840.7837.7821.9818.98
    1325032.85536.284517.3239.3336.3320.0417.04
    14








    15








    16








    17








    18








    Remarks: * are the reference values.

    Applications:

    1. Data Centers & Server Rooms: Use as a primary or patch backbone — 1000FT spool minimizes splices and ensures consistent signal over long rack-to-rack runs.
    2. Industrial Automation: Connect PLCs, HMIs, sensors and controllers in EMI-prone environments; FTP shielding protects critical control traffic.
    3. Commercial & Office Networks: Reliable workstation connectivity, VoIP, video conferencing and large office floor deployments.
    4. Retail & POS Systems: Long, clean runs to POS, inventory scanners and security systems; color-coded white jacket helps fast identification.
    5. 5G & Telecom Sites: Backhaul and local distribution in small cell or base station rooms where shielded cable reduces interference risks.


    Quality Cat6 ftp Shielded Lan Cable 1000ft Solid Copper Lszh Ethernet Cable For Data Centers for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Integrity Cable Co., Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)